Home
1
Products
2
AAP305 305Watt Single/Dual output Medical Open Frame Power Supply3
https://www.astekglobe.com/ Astek Globe
Astek catch your demand on Power Supply Astek catch Your Demand on Power Supplies ' https://www.astekglobe.com/Deutsche ”https://www.astekglobe.com/sp” ”https://www.astekglobe.com/fr” ”https://www.astekglobe.com/jp” "https://www.astekglobe.com" ”https://www.astekglobe.com/cn” ” https://www.astekglobe.com/zh” ”https://www.astekglobe.com”
Home Products Medical PCB power AAP305 305Watt Single/Dual output Medical Open Frame Power Supply
220

AAP305 305Watt Single/Dual output Medical Open Frame Power Supply

*Universal Input 100-240VAC *305W with Fan *Regulated Output with Low Ripple Noise *IEC/ANSI/AAMI ES60601-1(Ed. 3.1) *Size: 127 * 76 * 38mm *CEC/DoE VI, ErP step 2, No Load Power Consumption Less than 0.5W

58969989d5ffc93f622cc9b3ed0c6502.jpg

AAP305 305Watt
Single/Dual output Medical Open Frame power Supply  

Feature

*Medical Power Supply
*Mean of Protection: 2 * MOPP

*Universal Input 100-240VAC

*Single Output to 305W with Fan, Convection to 197~255watt

*Regulated Output with Low Ripple Noise
*On & off Remote control
*Touch current <100uA
*Meet CEC, DoE level VI, ErP Stage 2, No Load Power Consumption Less than
  0.5watt
*Standby 5V/1A
*Medical Power Design  IEC/EN/ANSI/AAMI ES60601-1(ed. 3.1), EMC: IEC60601-1-2:2014(ed. 4.0)

*Size: 5" * 3" *1.5", L 127* W 76 * H38mm 

*  UL60601, EN60601, IEC60601

*Modified and Custom Design available

*2 Years warranty

Input
Input Voltage: 90-264VAC
Frequency: 50/60Hz
Input current: 3.6-1.6A Max.

Protection: Internal Primary current fuse

Output

Part No     Output        Standby       Output watt with fan  Convection  

AAP305-S120   12V/25A       5V/1A                305                       197
AAP305-S240   24V/12.5A    5V/1A                305                        205
AAP305-S480   48V/6.25A    5V/1A                305                        205


1. Load Regulation: +/-5% (Typical)

2. Ripple:1% Vp-p Max. for Output Voltage @Full load

3. Transient Response: 0.5mS for 50% Load Change Typical

4. Hold up time: 10mS @Full load

5. Protection: Short Circuit /Over Voltage/Over Current/Over Temperature Protection

General Specification
Dielectric Withstand: 4000VAC Primary to Secondary

MTBF: 300,000 Calculated Hours at 25C, by Telcordia SR-332

Operating Temperature: 0-50 degree C
Storage Temperature: -20~80 degree C

Operating Humidity: 20~80% RH
Storage Humidity: 10% ~ 90% RH

Cooling: Cooling Convection
Safety and EMC: UL, cUL, CB, CE, FCC,CB

Dimension: (L) 127 * (W) 76* (H) 38 mm(open frame)          

Weight: open frame 350g
           

1482466