
APB050-USB 50W Battery 6ports USB
*Universal Input Voltage *6 Ports USB (5V/2.4A) *DOE VI, CoC Tier 2 VI Compliance *Low Rippple Noise
*Protection: Short Circuit, Over Current *Pass LVD, LPS *EN62368, IEC62368
Astek Gallium nitride (GaN) Desktop Power Adapter
SASO about Switching Power Supplies
GS Safety approval on Power Supply Units
Israel safety Approval about Switching Power Adapters
Argentina S-mark safety approval on Switching Power Adapters
*Universal Input Voltage *6 Ports USB (5V/2.4A) *DOE VI, CoC Tier 2 VI Compliance *Low Rippple Noise
*Protection: Short Circuit, Over Current *Pass LVD, LPS *EN62368, IEC62368
*output 48V/16.66A *Protections: Short Circuit/Overvoltage/Over Current/Over temperature *Application: Photographic Lamp *Compied with EN/IEC61347, CB, CE, FCC *Engergy Efficiency >=94% at 230VAC full load
*output 30V/12A *Constant Voltage *Protections: Short Circuit/Overvoltage/Over Current/Over temperature *Application: Photographic Lamp *Compied with EN/IEC61347, CB, CE, FCC *Engergy Efficiency >=93% at 230VAC full load
*output 48V/15A *Constant Voltage *Protections: Short Circuit/Overvoltage/Over Current/Over temperature *Application: Photographic Lamp *Compied with EN/IEC61347, CB, CE, FCC *Engergy Efficiency >=94% at 230VAC full load
*output 48V/30A *Protections: Short Circuit/Overvoltage/Over Current/Over temperature *Application: Photographic Lamp *Compied with EN/IEC61347, CB, CE, FCC *Engergy Efficiency >=94% at 230VAC full load
*Input 90-264VAC *Interchangeable US/China/EU/UK/SAA(Australia) /South Africa/India plug *Output 5V/9V/12V/24V *DOE VI, CoC Tier 2*Protections:Overcurrent/ Overvoltage * UL, cUL, CB, CE, FCC approved.* UL/IEC/EN62368-1, *one year warranty
*Medical Switching Power Supply *Universal Input 100-240VAC *Output 24V/8.3 A,5V/2A, max. 210W *ANSI/AAMI/IEC/ ES EN60601-1:2012 (60601 edition 3.1) *EMC: IEC60601-1-2:2014 (edition 4.0) *Means of Protection: 2 X MOPP *Modified and Custom Design available *2 Years warranty*2 Years warranty
*Input: 90~264VAC *Small Size: 3" * 5"*1.3" *IEC/EN/ANSI/AAMIES60601-1 Edition 3.1 *Means of Protection: 2 x MOPP*UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Meet CEC, DOE Level VI, ErP Stage 2, No Load Power Consumption Less than 0.21W
*Input: 90~264VAC *Small Size: 3" * 5"*1.3" *IEC/EN/ANSI/AAMIES60601-1 Edition 3.1 *Means of Protection: 2 x MOPP*UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Meet CEC, DOE Level VI, ErP Stage 2, No Load Power Consumption Less than 0.21W
*Output 42V/168Watt *Application: E bike *CC/CV charging Mode *10S battery pack use *For 42V Lithium-Ion Battery Charger *Battery Reverse Polarity Protection * No load Consumption <=0.21W, DOE VI
*Output 42V/84Watt *Application: E bike *CC/CV charging Mode *10S battery pack use *For 42V Lithium-Ion Battery Charger *Battery Reverse Polarity Protection * No load Consumption <=1W
*Input 90-264VAC *Output 5V/1A*Meet EISA 2007/DOE VI*Standard USB (Type A) connector*Protections:Over voltage/over temperature/Over current/Short Circuit* UL, cUL,CE, FCC approved *UL/EN/IEC62368-1, UL/EN/IEC60950-1*One year warranty
*Universal Input 100-240VAC *305W with Fan *Regulated Output with Low Ripple Noise *IEC/ANSI/AAMI ES60601-1(Ed. 3.1) *Size: 127 * 76 * 38mm *CEC/DoE VI, ErP step 2, No Load Power Consumption Less than 0.5W
*Input 100VAC~240VAC *Output 12V/15V/19V/20V//24V/48V/56V *C14/C6 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL 62368-1 *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/PSE/BSMI *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 100VAC~240VAC *Output 12V/19V/20V//24V/48V/56V *C14/C6 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL 62368-1 *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/PSE/BSMI *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 100VAC~240VAC *Output 12V/19V/24V/48V/56V *C8/C14/C6 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL 62368-1 *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/PSE/BSMI *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 100VAC~240VAC *Output 12V/15V/18V/19V/24V/48V *C18/C14/C6/C8 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL60601, *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/FCC/PSE *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 100VAC~240VAC *Output 12V/19V/24V/48V/56V *C18/C14 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL 62368-1, ANSI/AAMI/IEC/EN/UL60601, *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/PSE/BSMI *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 100VAC~240VAC *Output 12V/15V/19V/24V/48V/56V *C18/C14 inlet * Gallium Nitride Based Design *ANSI/AAMI/IEC/EN/UL 62368-1, ANSI/AAMI/IEC/EN/UL60601, *SCP/OVP/OCP/OTP *CB/UL/cUL/FCC/CE/PSE/BSMI *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Universal Input 100-240VAC *Regulated Output with Low Ripple Noise *Medical Power Design Also Provided *Size:3" * 2" * 0.9" footprint design, * UL62368-1, EN62368-1, IEC62368-1 *DoE VI, ErP step 2
*Medical Power Supply IEC/ANSI/AAMI ES60601-1 (edition 3.1) *Mean of Protection: 2 * MOPP *Size: 5" * 3" *1.5", L 127* W 76 * H38mm *2 Years warranty
*Universal Input 100-240VAC *Single Output to 305W *Regulated Output with Low Ripple Noise *Medical Power Design Also Provided *Size: 127 * 76 * 38mm footprint design,Enclosed 127*76*38mm * UL62368-1, EN62368-1, IEC62368-1, UL60601, EN60601, IEC60601 *DoE VI, ErP step 2
*Universal Input 100-240VAC *Single Output to 450W *Regulated Output with Low Ripple Noise *Medical Power Design Also Provided *Size: 127 * 76 * 34mm footprint design,Enclosed 127*87*50mm * UL62368-1, EN62368-1, IEC62368-1, UL60950-1, EN60950-1, IEC60950-1 *DoE VI, ErP step 2
*Universal Input 100-240VAC *Single Output to 600W *Regulated Output with Low Ripple Noise *Medical Power Design Also Provided *Size:L 203* W 127 * H40mm footprint design * UL62368-1, EN62368-1, IEC62368-1, UL60950-1, EN60950-1, IEC60950-1 *DoE VI, ErP step 2
* Input 90-264VAC *output 5V-48V*Protections: Short Circuit/Overvoltage/Over Current *2" * 4" in size* UL/ cUL60601-1,CB EN60601-1/IEC60601-1, CE, FCC approved.*100% burn-in test *one year warranty
*Medical Switching Power Supply *Universal Input 100-240VAC *Single Output to 150W *Size:127 *76 * 35mm footprint design *ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1) *IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available *2 Years warranty
*Input 90-264VAC *output 5V-48V *Protections: Short Circuit/Overvoltage/Over Current *2" * 4" in size* medical grade UL, cUL, CB, CE, FCC approved.*100% Burn-in and Hi-Pot tests *one year warranty
*Input 90-264VAC *output 5V-48V*Protections: Short Circuit/Overvoltage/Over Current *2" * 4" in size* UL/cUL60601-1, CB EN60601-1/IEC60601-1, CE, FCC approved.*100% Burn-in and Hi-Pot tests *one year warranty
*Medical Switching Power Supply *Universal Input 100-240VAC *Single Output to 600W *Size: 256 * 115 * 45mm footprint design *ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1) *IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available *2 Years warranty
*Medical adapter *Input 90~264VAC *Output 3V~58V*High Efficiency and reliability*Protections: Overcurrent/Overvoltage/Over Temperature* UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1), EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC, Means of Protection: 2 X MOPP, *Warranty 2years
*Input 100~240VAC *Output 5V~58V*DOE VI/CoC 5*Protection:Overcurrent/Overvoltage/Short Circuit *Means of Patient Protection Design*Possess risk analysis report** UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) * EMC: IEC60601-1-2:2014 (ED 4.0) *Two years warranty
*Input 90~264VAC *Output 5V~58V*DOE V/CoC 5 *Protections: Overcurrent/Overvoltage/Short Circuit*Means of Patient Protection Design*Possess risk analysis report*UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 *EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC *Means of Protection: 2 X MOPP
*Input 90~264VAC *Output 5V~58V*DOE VI/CoC 5*Protection:Overcurrent/ Overvoltage/Short Circuit*Means of Patient Protection Design *Possess risk analysis report *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP, *Two years warranty
*Input 100~240VAC *Output 5V~58V*DOE VI/CoC 5*Protection:Overcurrent/Overvoltage/Short Circuit *Means of Patient Protection Design*Possess risk analysis report** UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) * EMC: IEC60601-1-2:2014 (ED 4.0) *Two years warranty
*Input 90~264VAC *Output 5V~58V*DOE V/CoC 4 *Protections: Overcurrent/Overvoltage/Short Circuit*Means of Patient Protection Design*Possess risk analysis report*UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 *EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC *Means of Protection: 2 X MOPP
*Input 90~264VAC *Output 5V~58V*DOE V/CoC 4 *Protections: Overcurrent/Overvoltage/Short Circuit*Means of Patient Protection Design*Possess risk analysis report*UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 *EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC *Means of Protection: 2 X MOPP
*Input 90~264VAC *Output 5V~58V *DOE VI/CoC 5 *Protection:Overcurrent/ Overvoltage/Short Circuit *Means of Patient Protection Design*Possess risk analysis report *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP *Two years warranty
*Input 90~264VAC, Output 5V~58V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~58V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~58V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~58V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~24V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~24V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90~264VAC, Output 5V~24V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS, DOE VI/COC 5 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *UL/EN/IEC62368-1 *One year warranty
*Universal AC Input Range *DOE VI/COC 5 *Leakage current <0.25mA @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC approved, Pass LPS *One year warranty
*Input 90-264VAC *Output 12V/15V/19V/24V/52V Max. 120W *Protections: Short Circuit/Overvoltage/Over Current/Over Temperature*2" *4 " in size * UL, cUL, CB, CE, FCC approved.*UL/EN/IEC62368-1, UL/EN/IEC60950-1*100% Burn-in and Hi-Pot tests *One year warranty
*USB Power Delivery *Input 11~16VDC *output 5V/9V/12V/15V/20V max. 3A, max. 45W *DC DC Car Adapter*Input Voltage/Over Voltage/Over current/Over Temperature Protective Installatoin
*90~264VAC input voltage *compact size *output 12-56VDC max. 330wat *DOE VI, CoC 5 Tier 2 * UL/EN/IEC 62368-1, Slim Size*No load consumption<=0.5W
*90~264VAC input voltage *compact size *output 12-56VDC max. 200wat *DOE VI, CoC 5 Tier 2 *UL/EN/IEC 62368-1, UL/EN/IEC 60950-1, UL, cUL, CB, CE, FCC ,CCC
*90~264VAC input voltage *compact size *output 12-56VDC max. 48wat *DOE VI, CoC 5 Tier 2 *UL/EN/IEC 62368-1, UL/EN/IEC 60950-1, UL, cUL, CB, CE, FCC ,CCC
*Universal AC Input Range *Compact size *RoHS compliance*Active PFC function *Efficiency DOE VI, CoC 5 Tier 2 *Output 5~48V max. 48Watt, UL/EN/IEC 62368-1, UL/EN/IEC 60950-1, UL, cUL, CB, CE, FCC,CCC, approved
*90~264VAC input voltage *compact size *output 5-56VDC max. 48wat *DOE VI, CoC 5 Tier 2 *UL/EN/IEC 62368-1, UL/EN/IEC 60950-1, UL, cUL, CB, CE, FCC ,CCC
*Universal AC Input Range *Compact size *RoHS compliance*Active PFC function *Efficiency DOE VI, CoC 5 Tier 2 *Output 12~56V max. 90Watt meet UL/EN/IEC 62368-1, UL/EN/IEC 60950-1, UL, cUL, CB, CE, FCC compliance
*Medical Switching Power Supply *Universal Input 100-240VAC *Single Output to 65W *Size:102 *51 * 34mm footprint design *ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1) *IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available *2 Years warranty
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 5V/5.9V/9V/12V/15V/18V/24V/48V *ANSI/AAMI/IEC/ENES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0)*Protection:2 * MOPP * DoE VI、CoC Tier 2、NRCan、GEMS * Touch current<100uA; 10uA (optional)
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 5V/7.5V/9V/12V/15V/18V/24V *ANSI/AAMI/IEC/EN ES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0) *Means of Protection: 2 * MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 12V15V/18V//19V/20V/24V/48V *UL / cUL60601-1,ANSI/AAMI/IEC/EN ES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0) *Means of Protection: 2 * MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 12V15V/18V//19V/20V/24V/48V *UL/cUL60601-1,ANSI/AAMI/IEC/EN ES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0) *Means of Protection: 2 * MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available
*Input 90-264VAC *Output 12V/19V/24V/48V *UL/cUL60601-1,ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1) *EMC:IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available
*Universal Input Range *Protections: Short Circuit/ Overvoltage/Over Current *DOE VI/Coc Tier 2, NRCan, GEMS VI, CEC, Energy star, ErP stage 2 *Leakage current 0.25mA *Regulated Output with low ripple noise * UL, cUL, CB, CCC, BSMI, CCC, LPS, RCM, PSE, CE, FCC approved *IEC/UL/EN62368-1, IEC/UL/EN60950-1*Modified and Custom Design available
*Universal Input Range *Protections: Short Circuit/ Overvoltage/Over Current *DOE VI/Coc Tier 2, NRCan, GEMS VI, CEC, Energy star, ErP stage 2 *Leakage current 0.25mA *Regulated Output with low ripple noise * UL, cUL, CB, CCC, BSMI, CCC, LPS, RCM, PSE, CE, FCC approved *IEC/UL/EN62368-1, IEC/UL/EN60950-1 *Modified and Custom Design available
*Universal Input Range *Protections: Short Circuit/ Overvoltage/Over Current *DOE VI/Coc Tier 2, NRCan, GEMS VI, CEC, Energy star, ErP stage 2 *Leakage current 0.25mA *Regulated Output with low ripple noise * UL, cUL, CB, BSMI, LPS, PSE, CE, FCC approved *UL/EN/IEC62368-1, UL/EN/IEC60950-1*Modified and Custom Design available
*Universal Input Range *Protections: Short Circuit/ Overvoltage/Over Current *DOE VI/Coc Tier 2, NRCan, GEMS VI, CEC, Energy star, ErP stage 2 *Leakage current 0.25mA *Regulated Output with low ripple noise * UL, cUL, CB, CCC, BSMI, CCC, LPS, RCM, PSE, CE, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 approved *Modified and Custom Design available
*Medical Switching Power Supply *Universal Input 100-240VAC *Output 3.3V/5V/12V/15V/24V/48V *EMC: IEC60601-1-2:2014 (edition 4.0) *Modified and Custom Design available *2 Years warranty *2 x MOPP*DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available
*Universal Input Voltage range *Output 3.3V/5V/12V/15V/24V/48V,Protection: SCP/OVP/OCP * Size: 2“* 4”* UL,cUL,CB,CE,FCCapproved.*ANSI/AAMI/IEC/ ES EN62368-1, ANSI/AAMI/IEC/ ES EN60950-1* 100% burn-in and Hi-Pot test* DoE VI,ErP Step 2
*Input 100VAC~240VAC *Output 12V/18V/19V/24V/48V *C6/C14 inlet * DOE VI, CoC Tier 2 *ANSI/AAMI/IEC/EN/UL 62368-1, ANSI/AAMI/IEC/EN/UL60950-1, *SCP/OVP/OCP/OTP *LPS/LVD/CB/UL/cUL/FCC/CE/PSE *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 12V/18V/19V/24V/48V *UL/cUL60601-1,ANSI/AAMI/IEC/EN ES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0) *Means of Protection: 2 * MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available
*Medical Power Adapter * Input voltage 100-240VAC +/-10% *output 12V/19V/24V/48V *UL/cUL60601-1,ANSI/AAMI/IEC/EN ES60601-1:2012(60601 edition 3.1) * EMC: IEC60601-1-2:2014(edition 4.0) *Means of Protection: 2 * MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available
*Input 100VAC~240VAC *Output 12V/19V/24V/48V *C6/C14 inlet * DOE VI, CoC Tier 2 *ANSI/AAMI/IEC/EN/UL 62368-1, ANSI/AAMI/IEC/EN/UL60950-1, *SCP/OVP/OCP/OTP *LPS/LVD/CB/UL/cUL/FCC/CE/PSE *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS *Modified and customized design available
*Input 90~264VAC *output 15V/16V/18V/19V/20V/24V,C6 inlet*Efficiency: Level VI and CoC Tier 2/NRcan *EN/UL/IEC62368-1,IEC/UL/EN60950-1 *SCP/OVP/OCP *LPS/LVD*UL/cUL/CE/CB/FCC/VCCI/DOE VI/CoC/ErP step 2/RoHS/REACH/SVHC *one year warranty
*Input 90-264VAC *output 3.3V~48V*Protections: Short Circuit/Overload/Overvoltage*C8 inlet. *DOE VI/ErP*Pass LPS/LVD*100% Hi-Pot ;ATE Chroma test, and Burn-in tests *one year warranty *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/EN/IEC60950-1 *Modified and customized design available
*Input 100V/110V/120V/220V/240V *output 3V~30V, C8/C6/C14 inlet*Protection:Short Circuit/Overload/Overvoltage*USB socket provided.*DOE VI/ErP*Pass LPS/LVD,*DOE VI, cTUVus, TUV-GS, CB,CE, FCC, PSE, BSMI, NOM, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 *100% Hi-Pot &ATE Chroma test,100% Burn-in test
* Input 90-264VAC *output 3V~50V*Protection: Short Circuit/Overload/Overvoltage*USB socket provided.*DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Modified and customized design available*UL/cUL/CB/ LPS/LVD*100% Hi-Pot; ATE Chroma test,100% Burn-in test *one year warranty
* Input 90-264VAC *Output 3V~50V *Protections: Short Circuit/Overload/Overvoltage *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/EN/IEC60950-1 *Modified and customized design available* UL/cUL/LPS/LVD/cTUVus, TUV-GS, CB, CE, FCC, BSMI, VCCI, LVD *100% Hi-Pot & ATE Chroma test*100% Burn-in test *one year warranty
Input: 100-240VAC, Output: 12-56VDC,DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/EN/IEC 60950-1, Modified and customized design available, C8/C6/C14/C18 inlets, UL/cUL/CB/CCC/CE/FCC approved, SCP/OVP/OCP/OTP, one year warranty, 100% burn-in test
*Universal AC Input Range *Protections: Short Circuit/Overload/Overvoltage*DOE VI/ErP *Pass LPS/LVD *IEC/UL/EN62368-1, IEC/UL/EN60950-1*100% Hi-Pot & ATE Chroma test*100% Burn-in test
*Input 100-240(+/-10%) *output 9V~48V *US/EU/AU/UK wall/interchangeable plug, USB socket *IEC/EN/UL 62368-1, IEC/EN/UL60950-1*Protections: Short Circuit/Overload/Overvoltage *DOE VI/ErP*Pass LPS/LVD*100% Hi-Pot & ATE Chroma test *100% Burn-in test
*Input 100-240VAC *wall mount/trave/USB adapter*Protections: Short Circuit/Overload/Overvoltage*DOE VI/ErP *Pass LPS/LVD*100% Hi-Pot & ATE Chroma test *IEC/EN/UL 62368-1, IEC/EN/UL60950-1 *100% Burn-in test *one year warranty
* Input 100-240VAC +/-10%
*Output 10~48VDC
*IEC/EN/UL 62368-1, IEC/EN/UL60950-1
*Interchangeable US/EU/UK/AU/China plug adapter
*Protections: Short Circuit/Overload/ Over voltage
*DOE VI/ErP
*Pass LPS/LVD
*Application: Industrial/Laptop and others for power adapters and chargers
*100% Hi-Pot and burn-in test
*one year warranty
* Input 90-264VAC *output 3V~50V*Protection: Short Circuit/Overload/Overvoltage*USB socket provided.*DC cable with USB type C connector*DOE VI/ErP*UL/cUL/CB/ LPS/LVD *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *100% Hi-Pot; ATE Chroma test,100% Burn-in test *one year warranty
*Universal AC Input Range*Protection:Short Circuit/Overload/Overvoltage*USB socket provided. *DC cable with USB type C connector*DOE VI/ErP*Pass LPS/LVD *UL/EN/IEC62368-1, UL/EN/IEC60950-1*100% Hi-Pot &ATE Chroma test,100% Burn-in test
*Input 90~264VAC *output 3V~ 15V*USB socket provided *DC cable with USB type C connector*Efficiency: Level VI and CoC Tier 2 *EN62368,IEC62368 *SCP/OVP/OCP *LPS/LVD*UL/cUL/CE/CB/FCC/VCCI/DOE VI/CoC/ErP step 2/RoHS/REACH/SVHC *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *one year warranty
*Input 90-264VAC *output 5V/12V *Efficiency: Level VI and CoC Tier 2 *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *SCP/OVP/OCP *LPS/LVD *USB socket provided *DC cable with USB type C connector *UL/cUL/CE/FCC/CB/VCCI/DOE VI/ErP step 2/CoC/RoHS/SVHC/REACH *one year warranty
*Input 90~264VAC *output 3V-15V*Protection: Short Circuit/Overload/Overvoltage*USB Socket provided*DOE VI/ErP*Pass LPS/LVD *100% Burn-in test *UL/cUL/CE/FCC/VCCI/CB/DOE VI/CoC/ErP step 2/RoHS/REACH/SVHC *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *one year warranty *USB socket provided *DC cable with USB type C connector
*Input 90-264VAC *output 12-48V *Protections: Short Circuit/Overvoltage/Over Current *2" * 4" in size* UL/cUL60601-1, CB EN/IEC60601-1, CE, FCC approved.*100% Burn-in test
*Input 90-264VAC *Output 5-56V *Protections: Short Circuit/Overvoltage/Over Current*3" * 5" in size *U-channel also provided *IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available
*Input 90-264VAC *Output 5-48V *Protections: Short Circuit/Overvoltage/Over Current*3" * 5" in size *U-channel also provided *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1), IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA *Modified and Customized design available
* Input 90-264VAC *output 12-24VDC DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, IEC/EN/UL 60950-1*Modified and customized design available *Protections: Overcurrent/ Overvoltage/Over Temperature/Short Circuit * UL,cUL, CB, CE, FCC approved.*C6 inlet, Size: 172*87*27(mm) *100% burn-in test *one year warranty
* Input 90-264VAC *output 12-56VAC *Protections: Overcurrent/ Overvoltage/Over Temperature/Short Circuit * UL,cUL, CCC, CB, CE, FCC approved.*IEC/EN/UL62368-1, IEC/EN/UL60950-1*C6/C14/C18/C8 inlet
*Input 90-264VAC *output 12-56VDC *Active PFC function *Led indication *Protections: Short Circuit/ Overvoltage/Overcurrent/Over Temperature *UL/cUL60601-1, ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1)*IEC60601-1-2:2014 (edition 4.0)*2 x MOPP*DoE VI, CoC Tier 2, NRCan,GEMS*Touch Current <100uA or <10uA (optional) *Modified and Customized design available
* Input 90-264VAC *output 18-24VAC *Protections: Overcurrent/ Overvoltage/Over Temperature/Short Circuit * UL,cUL, cTUVus, CB, CE, FCC approved.*C8 inlet, Size: 98*65*16.8(mm) *meet UL/IEC/EN62368-1, UL/IEC/EN60950-1*100% burn-in test *one year warranty
*Input 90-264VAC *output 12V-24V *Active PFC function *Protections:Overcurrent/ Overvoltage *Comply with DOE VI/ErP *UL, cUL,CB, CE, PSE, EK, PSB, CCC, CE, VCCI, LVD, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/IEC/EN60950-1 approved *100% burn-in test *one year warranty
*Input 90-264VAC *output 12V-56V *Active PFC function*Protections:Overcurrent/ Overvoltage/Short Circuit *Comply with DOE VI/ErP* UL, cUL62368-1, EN/IEC60950-1, IEC/EN62368-1, UL60950-1CB, CE, PSE *100% burn--in test *one year warranty
*Input 90-264VAC *output 12V-24V *Active PFC function*Protections:Overcurrent/ Overvoltage *Comply with DOE VI/ErP*UL, cUL,CB, CE, PSE, EK, BSMI, CE, VCCI, LVD, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC 60950-1approved *100% burn-in test *one year warranty
* Input 90-264VAC *output 12V-56V *C14/C6/C8/C18 inlet *Active PFC function*Protections:Overcurrent/ Overvoltage/Over Temperature * DOE VI/ErP*UL, cUL, CB, CCC, CE, VCCI, LVD, FCC, UL62368-1, EN62368-1, IEC62368-1,UL/EN/IEC 60950-1 approved *100% burn-in test *one year warranty
*Input 90-264VAC *output 12V-24V *C6/C14 AC inlet *Protections: Overcurrent/ Overvoltage * UL, cUL, CB, CE, VCCI, LVD, FCC approved. *100% burn-in test *one year warranty *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS,UL/EN/IEC 62368-1, UL/EN/IEC 60950-1 *Modified and customized design available
* Input 90-264VAC *output 15V-24V *Protections: Overcurrent/Overvoltage/Over Temperature/Short Circuit * cTUVus, CB, UL, cUL, BSMI, PSE, CE, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 approved.*C8 inlet, Size: 93*58*16.8mm *100% burn-in test *one year warranty
*Input 100-240VAC(+/-10%) *output 15V-24V *Protections: Overcurrent/Overvoltage/Over Temperature/Short Circuit * cTUVus, CB, UL, cUL, BSMI, PSE, CE, FCC, meet UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1.*C8 inlet, Size: 93*58*16.8mm *100% burn-in test *one year warranty
*Input 90-264VAC *output 5V-48V *C6/C8/C14/C18 inlet *DOE VI, CoC Tier 2 *Protections:Overcurrent/ Overvoltage * UL/cUL62368-1, CB, EN/IEC62368-1, UL/EN/IEC60950-1 and CE, FCC approved.*100% Burn-in test *One year warranty
*Input 90-264VAC *Interchangeable US/China/EU/UK/SAA(Australia) /South Africa plug *Output 5V-24V *DOE VI, CoC Tier 2*Protections:Overcurrent/ Overvoltage * UL, cUL, CB, CE, FCC approved.* UL/IEC/EN62368-1, UL/IEC/EN60950-1*one year warranty
*Input 90-264VAC *Output 5V~48V *DOE VI/CoC Tier 2*Protections: Overcurrent/ Overvoltage * UL, cULUL/IEC/EN62368-1, UL/IEC/EN60950-1, CE, FCC approved.*US/EU/UK/Australia(SAA) plug *100% burn-in test *one year warranty
*Input 90~264VAC *Output 5V~58V *DOE VI/CoC 5*Protection:Overcurrent/Overvoltage/Short Circuit*Means of Patient Protection Design*Possess risk analysis report* UL / cUL60601-1,IEC / EN / ANSI / AAMI ES 60601-1(ED 3.1),EMC:IEC60601-1-2:2014(ED 4.0),CE,FCC,Means of Protection:2 X MOPP*Two years warranty
*Input 90~264VAC, Output 5V~24V *Means of Patient Protection Design *Possess risk analysis *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1-11, EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP
*Input 90-264VAC *output 12-56VDC *Protections: Short Circuit/Overvoltage/Over current/Over Temperature*DOE VI or V*Application:Medical power, Medical charger(CV mode) *UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1)* EMC: IEC60601-1-2:2014 (ED 4.0)* Means of Protection: 2 X MOPP *one-year warranty
*Input 90-264VAC *Output 12-56V *Protections: Short Circuit/Overvoltage/Over current/Over Temperature *DOE VI or V*UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1)*EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC*Means of Protection: 2 X MOPP, CE and FCC approved *one year warranty
*Input 90~264VAC *Output 12V~56V *Protections: Short Circuit/Overvoltage/Over current/Over Temperature*DOE VI or V*UL/cUL60601-1, IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) *EMC: IEC60601-1-2:2014 (ED 4.0), CE, FCC *Means of Protection: 2 X MOPP *One-year warranty
*Input 90~264VAC *Output 12V~24V*Protections: Short Circuit/Overvoltage*ANSI/AAMI/IEC/EN/ES 60601-1:2012 (60601-1 edition 3.1) *UL/cUL60601-1, IEC60601-1-2:2014 (edition 4.0) *2 x MOPP *DoE VI, CoC Tier 2, NRCan,GEMS *Touch Current <100uA or <10uA (optional) *Modified and Customized design available *Application: Medical power, Medical charger *One year warranty
*Input 90-264VAC *Output 5V~48V *DOE VI/DOE V (optional)*Protections: Overcurrent/ Overvoltage * UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) * EMC: IEC60601-1-2:2014 (ED 4.0)
* Means of Protection: 2 X MOPP .*Application: Medical charger, medical adaptor *one year warranty
*Input 90-264VAC **Output 5V-48V *DOE VI/DOE V (optional)*Protections:Overcurrent/ Overvoltage * UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1) * EMC: IEC60601-1-2:2014 (ED 4.0) * Means of Protection: 2 X MOPP*Application: Medical charger, medical adaptor *one year warranty
*Input 90-264VAC *output 5V-48V *DOE VI/DOE V (optional)*Protections:Overcurrent/ Overvoltage *UL/cUL60601-1,IEC/EN/ANSI/AAMI ES 60601-1 (ED 3.1), EMC: IEC60601-1-2:2014 (ED 4.0), Means of Protection: 2 X MOPP, .*Application: medical charger, medical adapter *one year warranty
*Input 90~264VAC *Output 12V~48V *Protections: Short Circuit/Overvoltage/Over Current*2" * 4" in size *100% Burn-in and Hi-Pot tests*UL/EN/IEC62368-1, UL/EN/IEC60950-1, CB, CE/FCC/SVHC/ROHS/REACH *one year warranty *DoE VI, ErP step 2
*Input 90-264VAC *Output 5-48V *Protections: Short Circuit/Overvoltage/Over Current*3" * 5" in size * UL, cUL, CB, CE, FCC approved. *UL/EN/IEC62368-1, UL/EN/IEC60950-1*U-channel provided *100% Burn-in and Hi-Pot tests *One year warranty
*Input 90-264VAC *output 5V-56V *Protections: Short Circuit/Overvoltage/Over Current*3" * 5" in size * UL, cUL, CB, CE, FCC approved.*UL/EN/IEC62368-1, UL/EN/IEC60950-1*U-channel also provided*100% Burn-in and Hi-Pot tests *one year warranty
*Input 100~240VAC *output 12-56V , *C14/C18/C8/C6 inlets*DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1 *Modified and customized design available *Low ripple noise*Protections: Overcurrent/ Overvoltage/Over temperature *UL, cUL, CB,CCC, CE, VCCI, LVD, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC 60950-1approved *100% burn-in test *one-year warranty
*Input 90~264VAC *output 12-24V *High efficiency *Low ripple noise*Protections: Overcurrent/ Overvoltage *UL, cUL, CB,CCC, CE, FCC approved *100% burn-in test *one-year warranty *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, IEC/EN/UL 60950-1*Modified and customized design available
* Input 9V-30VDC *Output 5V-48VDC*High Reliability and Efficiency*Optional Output connectors*Constant Current (CC) mode*OVP/OCP/SCP*One year warranty*Low Ripple Noise*Application: Car charger, Automobile charger, Vehicle adapter
*Input 90-264VAC *Output 5V/2.4A *Efficiency: Level VI and CoC Tier VI *Short Circuit Protection/Over Voltage Protection/Over Current Protection *LPS/LVD *UL/EN/IEC62368-1, UL/EN/IEC60950-1*one year warranty
*Input 90~264VAC *output 3V~ 15V*Efficiency: Level VI and CoC Tier 2 *UL-62368-1, EN62368,IEC62368, UL/EN/IEC60950-1 *SCP/OVP/OCP *LPS/LVD*UL/cUL/CE/CB/FCC/VCCI/DOE VI/CoC/ErP step 2/RoHS/REACH/SVHC *one year warranty
*Input 90-264VAC *Output 5V,12V *Efficiency: Level VI and CoC Tier V *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Short Circuit Protection/Over Voltage Protection/Over Current Protection *LPS/LVD *One year warranty
*Input 90-264VAC *output 5V/12V *Efficiency: Level VI and CoC Tier 2 *UL/IEC/EN62368-1, UL/IEC/EN60950-1 *SCP/OVP/OCP *LPS/LVD *UL/cUL/CE/FCC/CB/VCCI/DOE VI/ErP step 2/CoC/RoHS/SVHC/REACH *one year warranty
*Input: 90~264VAC Output:12V/5A,54V/7.34A *Small Size: 3" * 5"* 0.9" footprint design *Compact size*High
Efficiency*Industrial power supply *UL, cUL, CB, CE *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *One year warranty
*Input 90~264VAC *Output 24V/54V, *Small Size: 3" * 5"* 0.9" footprint design *High Efficiency *OVP/OLP/SCP *UL/CUL/CB/CE *UL/EN/IEC62368-1, UL/EN/IEC60950-1*Industrial/Medical power supply
*Input 100-240V, Output 12V/15V/19V/24V/30V/48V/56V *C14/C6/C8 inlet *UL/cUL/CB/BSMI/CCC/PSE/CE/VCCI/LVD/FCC, IEC62368-1, EN62368-1, UL62368-1, IEC/EN/UL60950-1 *Protections: Short Circuit/Overload/ Overvoltage *DOE VI/ErP *one year warranty *100% burn-in test*Application: IT/Industrial, Telecom
*Input 100~240VAC *Output 12~58V *C14/C6/C8 inlet*Protections: Short Circuit/Overload/ Overvoltage UL/cUL/CB/PSE/CE/FCC/VCCI/LVD,.UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC 60950-1*100% burn-in test *one year warranty *Application: IT/Industrial, Telecom
*input 10.5-28VDC *output 3-9VDC *DC DC Car Adapter*Protections:Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High AmbientTemp(40°C)*Application:Car charger,Automobile charger*one year warranty
*Input 12-24VDC *output 12~24VDC*DC DC Car Adapter*Protections: Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High Ambient Temp(40°C)*Application: Car charger, Automobile charger *One year warranty
*Input 10.8-28VDC *12~24VDC *DC DC Car Adapter*Protections:Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High AmbientTemp(40°C)*Application:Car charger,Automobile charger **One year warranty
*Input 10.5-28VDC *Output 5V-24VDC*DC DC Car Adapter*Protections:Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High AmbientTemp(40°C)*Application:Car charger,Automobile charger *one year warranty
* Input 90~264VAC *output 12V~48V*Protections: Short Circuit/Overload/ Overvoltage* 2 steps Charging Led Indicator *Charging with Constant Voltage mode*High Efficiency *100 % burn-in test *one year warranty *UL/EN/IEC62368-1, UL/EN/IEC60950-1
*input 10.5-28VDC *output 3-24VDC *DC DC Car Adapter*Non-Isolated*Protections: Short Circuit/Overcurrent/ Overvoltage *Low Ripple Noise*100% Burn-in test High ambient temp(40°C)*Application: Car charger *One year warranty
*Input 10.5-28VDC *Output 3V~9V*DC DC Car Adapter*Non-Isolated*Protections: Short Circuit/Overcurrent/ Overvoltage*Low Ripple Noise *100% Burn-in test High Ambient Temp(40°C)*Application:Car charger *One year warranty
*Input 11V-15VDC *Output 15-24VDC *DC DC Car Adapter*Protections:Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High AmbientTemp(40°C)*Application:Car charger,Automobile charger *One year warranty
*Input 10.5-28VDC *Output 12-24VDC*DC DC Car Adapter*Protection:Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise *100% Burn-in test High AmbientTemp(40°C)*Application:Car charger,Automobile charger *one year warranty
*input 10.8V-28VDC *Output 110~24VDC*DC DC Car Adapter*Protections: Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High ambient temp(40°C)*Application: Car charger, Automobile charger *one year warranty
*Input 10.5-15VDC *Output 12-24VDC *DC DC Car Adapter*Protections: Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise *100% Burn-in test High ambient temp(40°C)*Application:Car charger, Automobile charger *one year warranty
*Input 10.5-16VDC *output 15-24VDC *DC DC Car Adapter*Protections: Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise *100% Burn-in test High AmbienTemp(40°C)*Application: Car charger, Automobile charger*one year warranty
*input 10.8V-16VDC *12V~27VDC*DC DC Car Adapter*Protections: Short Circuit/Overcurrent/Overvoltage*Low Ripple Noise*100% Burn-in test High Ambient Temp(40°C)*Application:Car charger,Automobile charger *One-year warranty
*DC DC Car Adapter* Input 12V-24VDC*High Reliability and Efficiency*Compact package *One year warranty*Low Ripple Noise*Application: Car charger *one year warranty
*DC DC Car Adapter*Input 12VDC-24VDC*Output 5V/2.4A, 5V/2.4A *High Reliability and Efficiency*Compact package *One year warranty*Low Ripple Noise*Application: Car charger
*Input 100~240VAC *Output 8~50V *Pass LPS,class2 *8V~50V *Constant volt &constant current mode*LED indicator shows loading status *High Efficiency & Reliability *UL/EN/IEC62368-1
*input VAC *output 5V-48V *Pass LPS*High Efficiency & Reliability*Protection:Overvoltage/over current/Short Circuit *Compact package * UL, cUL, CB,LPS, CE, FCC approved. *100% burn-in test *Warranty one year *UL/EN/IEC62368-1, UL/EN/IEC60950-1
*Input 90~264VAC *Output 5V~48V *Pass LPS*High Efficiency & Reliability*Protections: Overvoltage/over current/Short Circuit *Compact package * UL, cUL, CB,LPS, CE, FCC approved. *Warranty one year *UL/EN/IEC62368-1, UL/EN/IEC60950-1
*Input 90~264VAC *Output 5V/1A*Meet EU ErP/COC 5*Standard USB (Type A) connector*Protections: Over voltage/over temperature/Over current/Short Circuit*TUV-GS, CE approved.*UL/EN/IEC62368-1, UL/EN/IEC60950-1*Warranty one Year
* input 90-264VAC *output 5V-48V*Meet EU ErP/COC 5; EISA 2007/DoE VI*Standard USB(Type A)connector*Optional output connector; Optional D+/D- define*Protection:Over voltage/ Over current/Short Circuit *UL, cUL, TUV-GS, CE, FCC, PSE, CB, LPS *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *one year warranty
*Input 90-264VAC *Output 3.3V-48VDC *Meet EU ErP/COC 5; EISA 2007/DoE VI*Standard USB(Type A)connector*Optional output connector; Optional D+/D- define*Protection:Over voltage/ Over current/Short Circuit *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *one year warranty
*input 90-264VAC *output 3V-48V*Pass LPS *High Efficiency & Reliability *Protections: Overvoltage/over current/Short Circuit *Compact package UL,cUL,CB,LPS, CE,FCC approved*Warranty one year *UL/EN/IEC62368-1, UL/EN/IEC60950-1
*Input 12~24VDC *output 5V/1A*DC DC Car Adapter*Wide Input Voltage 12VDC to 24VDC*High Reliability and Efficiency*Compact package *One year warranty*LowRipple Noise*Application: Car charger *one year warranty
*Input 12~24VDC *Output 5V/2.1A*DC DC Car Adapter *high reliability* Efficiency*Compact package*One year warranty*LowRipple Noise*one year warranty
*Input 90~264VAC *Output 3.3~56V*Small Size: 2" * 4"* 1.02" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Application:Industrial, Printer, Network System, Telecommunication, and Storage*One year warranty *Output Power up to 50W
*Input 90~264VAC *Output 3.3~48V*Small Size: 2" * 4"* 1.02" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1*Application:Industrial, Printer, Network System, Telecommunication and Storage *One year warranty*Output Power up to 65W
*Input 90~264VAC *Output 12~56V*Small Size: 2" * 4"* 1.12" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1*Application:Industrial, Printer, Network System, Telecommunication and Storage System.*One year warranty*Output Power up to 100W
*Input 90~264VAC *Dual Output 5V/1.0~6.4A/1.0~10A/11A, 12V/0~4.0A/0~6.0A/6.6A*Small Size: 3" * 5"* 1.34" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Compact size*High Efficiency*Industrial Power Supply *One year warranty
*Input 90~264VAC *Output 12~48V*Small Size: 3" * 5"* 0.79" or 2.5" * 5" * 0.79" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1*Compact size*High Efficiency*Industrial power supply *One year warranty *DoE VI, ErP step 2
*Input 90~264VAC, *Output 12~56V*Small Size:3"*5"*1" footprint design*Application: Industrial,
Printer, Network System, Telecommunication and Storage System.*Output Power up to 200W.48V-56V suitable *UL/EN/IEC62368-1, UL/EN/IEC60950-1*One year warranty *DoE VI, ErP step 2
*Input 100-240(+/-10%) *output 15-24V*Meets EN55022 Class B and CISPR/FCC Class B, meet UL/EN/IEC62368-1, UL/EN/IEC60950-1. *Protections: Short Circuit/Overload/ Overvoltage*Pass LPS/LVD*Size: 110*58*18(mm) *100% Hi-Pot test
*Input: 100-240VAC *Meets EN55022 Class B and CISPR/FCC Class B, UL / IEC / EN62368-1, UL / IEC / EN60950-1 *Protections: Short Circuit/Overload/Overvoltage *High Efficiency *Pass LPS/LVD *100% Hi-Pot and burn-in test
*Input 90~264VAC *Output 12V/24V/48V/56V *Small Size: 3" * 5" footprint design *UL/EN/IEC62368-1, UL/EN/IEC60950-1 *Application: Industrial, Printer, Network System, Telecommunication and Storage System.*Output Power up to 200W.48V-56V suitable*One year warranty *DoE VI, ErP step 2
*Input 90~264VAC *output 3V-15V*Protection: Short Circuit/Overload/Overvoltage*USB Socket provided*DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, UL/IEC/EN62368-1, UL/IEC/EN60950-1 *Modified and customized design available *Pass LPS/LVD *100% Burn-in test *UL/cUL/CE/FCC/VCCI/CB/DOE VI/CoC/ErP step 2/RoHS/REACH/SVHC *one year warranty
* Input 90-264VAC *output 3V~50V*Protection: Short Circuit/Overload/Overvoltage*USB socket provided.*DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/EN/IEC60950-1 *Modified and customized design available *UL/cUL/CB/ LPS/LVD*100% Hi-Pot; ATE Chroma test,100% Burn-in test *one year warranty
*Input 90-264VAC *Dual or Triple output*Protections: Short Circuit/ Overvoltage/Over Current *DOE VI/COC 5/UL, cUL, CB, PSE, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 *C6/C8/C14 inlet *100% burn-in test *one year warranty
* Input 90-264VAC *Output 3V~50V *Protections: Short Circuit/Overload/Overvoltage *DOE VI/ErP/ LPS/LVD/cTUVus, TUV-GS, CB, CE, FCC, BSMI, VCCI, LVD *100% Hi-Pot & ATE Chroma test*100% Burn-in test *one year warranty *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1 *IEC/UL/EN62368-1, IEC/UL/EN60950-1*Modified and customized design available
*Universal AC Input Range *output 12V/24V/48V/56V *C8/C6/C14 inlet *Protections: Short Circuit/Overload/Overvoltage *DOE VI/ErP/ UL/cUL/TUV-GS/CB/BSMI/CE/VCCI/LVD, UL/EN/IEC62368-1, UL/EN/IEC60950-1 approved.*1 year warranty
*Universal AC Input Range *Protections: Short Circuit/Overload/Overvoltage*DOE VI/ErP, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 *Pass LPS/LVD*100% Hi-Pot & ATE Chroma test*100% Burn-in test
*Input 100-240VAC Output 12V/15V/19V/24V/48V/56V *C6/C8/C14 inlet *Protections: Short Circuit/Overload/Overvoltage*DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/EN/IEC60950-1 *Modified and customized design available *UL/cUL/TUV-GS/CB/BSMI/PSE/ CE/VCCI/LVD approved.*1 year warranty
*Input 100-240VAC *DOE VI/COC 5 *Dual or Triple outputs *C6/C14 inlet *Leakage current <3.5mA/class I @240VAC/50Hz * UL, cUL, CB, PSE, CB, CE, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 approved*One year warranty
*Input 100-240(+/-10%) *output 9V~48V * USB socket, C6/C8/C14 inlet *Protections: Short Circuit/Overload/Overvoltage *DOE VI/ErP, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1*Pass LPS/LVD*100% Hi-Pot & ATE Chroma test *100% Burn-in test
*Input 90-264VAC *output 12~56VDC * UL, cUL,TUV-GS, CB, BSMI, CE, FCC, VCCI, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1 approved *Protections: Short Circuit/Overload/ Overvoltage*DOE VI/ErP *100% burn-in test **one-year warranty *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, *Modified and customized design available
*Input 100-240VAC *desktop C6/C14/C8 inlet adapter*Protections: Short Circuit/Overload/Overvoltage*DOE V, /ErP UL,cUL, TUV-GS, CB,CE, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC60950-1*Pass LPS/LVD*100% Hi-Pot & ATE Chroma test *100% Burn-in test *one year warranty
* Input 90-264VAC *Output 10~48VDC*Desktop C8/C6/C14 inlet *Protections: Short Circuit/Overload/ Overvoltage*DOE VI/ErP*Pass LPS/LVD *UL,cUL, TUV-GS, CB,CE, FCC, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC 60950-1*100% Hi-Pot and burn-in test *one year warranty
*Input 90-264VAC *output 12~56VDC *DOE VI, UL, cUL,TUV-GS, CB, BSMI, UL62368-1, EN62368-1, IEC62368-1, UL/EN/IEC 60950-1 *Protections: Short Circuit/Overload/ Overvoltage*DOE VI/ErP step 2 Application: IT/Industrial, Telecomm *100% burn-in test *one-year warranty
*Input 90~267VAC *Output 12~24VDC *DOE VI, CoC Tier 2, ErP stage 2, NRCan, GEMS, IEC/EN/UL 62368-1, UL/IEC/EN 60950-1 *UL, cUL,TUV-GS, CB, BSMI, CE, VCCI, LVD *Protections: Short Circuit/Overload/ Overvoltage *Application: IT/Industrial, Telecom *100% burn-in test*one-year warranty *Modified and customized design available